Search results for "Contact test"
showing 5 items of 5 documents
Antimicrobial activity and enterococcus faecalis biofilm formation on chlorhexidine varnishes.
2011
Objective: To evaluate, in vitro, the antimicrobial activity and biofilm formation of three chlorhexidine varnishes in four Enterococcus faecalis strains: E. faecalis ATCC 29212, E. faecalis EF-D1 (from failed endodontic treatment), E. faecalis 072 (cheese) and E. faecalis U-1765 (nosocomial infection), and one Enterococcus durans strain (failed endodontic treatment). Study Design: The direct contact test was used to study the antimicrobial activity. Bacterial suspensions were exposed for one hour to EC40, Cervitec (CE) and Cervitec Plus (CEP) varnishes. “Eradication” was defined as 100% bacterial kill. The formation of enterococci biofilms was tested on the surface of the varnishes after 2…
Biological and physico-chemical properties of new root canal sealers
2018
Background The purpose of the present study was to compare the biological and the physico-chemical properties of bioceramic-based root canal sealers, calcium hydroxide-based, MTA-based and epoxy resin-based root canal sealers. Material and methods Two bioceramic-based sealers, one calcium hydroxide-based sealer, one MTA-based sealer and two epoxy resin-based sealers were tested. Results EasySeal and MTA Fillapex showed severe citotoxic activity, AH Plus and SealapexTM moderate cytotoxicity, BioRoot™ RCS and TotalFill BC Sealer were both cytocompatible. Except for TotalFill BC Sealer, all root canal sealers caused inhibition zones when tested with E. faecalis. The highest inhibition zone was…
Antibacterial, physical and mechanical properties of bonding agent containing synthesized Zinc Dimethacrylate
2019
Background The aim of this study includes synthesis of zinc dimethacrylate ionomer (ZDMA) by a new method, incorporate it into resin bonding and evaluate its antibacterial, physical and mechanical properties. Material and methods Resin adhesives containing 0 to 5% wt of ZDMA was produced and the following tests were accomplished: A: Antibacterial test: 1.Direct contact test. 2.Material aging; in both of them the bacterial colony counting were performed. B: Physical test: 1.Degree of conversion (D.C). 2.Evaluating the amount of released Zinc ion release in aqueous medium. C: Mechanical test: 1.Compressive strength test. 2.Shear bond test (enamel and dentine separately). The obtained results …
In vitro antibacterial activity of endodontic sealers
2004
Summary Objectives To evaluate the antibacterial activity of four endodontic sealers: one epoxy resin sealer (AH Plus), two zinc oxide eugenol (ZOE)-based sealers (Endomethasone, Pulp Canal Sealer), and one sealer containing both ZOE and orthophenilphenol (Vcanalare). Methods A direct contact test (DCT) was performed. A 10 μl suspension of Enterococcus faecalis was placed on the test material 20 min, 24 h and 7 days after mixing. Bacteria were allowed to directly contact the sealers for 1 h at 37 °C. Bacterial growth was then spectrophotometrically measured every 30 min for 7 h, and again after 24 h as well. Results All freshly mixed sealers showed complete inhibition of bacterial growth. S…
In vitro evaluation of the antibacterial activity of cured dentin/enamel adhesive incorporating the antimicrobial agent MDPB
2010
The aim of this study was to investigate in vitro the antibacterial effect of a dentin/enamel adhesive containing MDPB (Clearfil Protect Bond) after curing and to compare it with an adhesive not containing MDPB (Clearfil SE Bond). The antibacterial effect of the cured adhesives was tested on Enterococcus faecalis by the evaluation of growth inhibition in a 48-h microplate direct contact test (DCT). The presence of antibacterial activity due to soluble components was also investigated by an agar diffusion test (ADT) performed with the adhesives cured on the surface of dentin disks. In the DCT, both the tested materials showed complete inhibition of bacterial growth until the 7-h reading, reg…